Syndetics cover image
Image from Syndetics

Wastewater treatment plant design and operation modifications to improve management of biosolids : regrowth, odors, and sudden increase in indicator organisms / by Matthew J. Higgins, Sudhir N. Murthy.

By: Contributor(s): Material type: TextTextPublisher: Alexandria, Virginia : WERF, 2015Copyright date: ©2015Description: 1 online resource (150 pages) : illustrations, graphsContent type:
  • text
Media type:
  • computer
Carrier type:
  • online resource
ISBN:
  • 9781780404578 (ebook)
Subject(s): Genre/Form: DDC classification:
  • 628.1683 23
LOC classification:
  • TD730 .H544 2015
Online resources:
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Call number Status Date due Barcode Item holds
Ebrary Online Books Ebrary Online Books Colombo Available CBEBK20002168
Ebrary Online Books Ebrary Online Books Jaffna Available JFEBK20002168
Ebrary Online Books Ebrary Online Books Kandy Available KDEBK20002168
Total holds: 0

Enhanced descriptions from Syndetics:

Available as eBook only
The overall goal of this project was develop approaches to manage the issues of regrowth, odors, and sudden increase (ROSI) of indicator and pathogenic bacteria in biosolids.
The project entailed two phases. The first phase was focused on filling critical research gaps that provided the fundamental insights for developing solutions to these issues which includes method development. The second phase focused on developing and implementing solutions in the field.
The hypothesis that sudden increase is a result of incomplete inactivation of indicators was supported by the results from this work. The results suggest that Method 1680 underestimates the viable density of indicators in samples after thermal treatment. In addition, that results showed that to achieve complete inactivation of indicators, a slightly higher time-temperature regime will be needed and this new "best practices" time-temperature curve has been developed as part of the work. It should be emphasized that the current EPA time-temperature requirements appear to be sufficient for Salmonella , the bacterial pathogen used in the regulations. Several processes that utilize temperature about 75°C were able to eliminate SI. Gas chromatography-olfactometry was used to identify the persistent/long term odorants in centrifuged biosolids. The main persistent odorants contributing to cake odors were indole, skatole, p-cresol, and butyric acid. Interestingly, all of these compounds are breakdown products of organics such as proteins, carbohydrates and fats, suggesting that processes which eliminate these precursors will help reduce odors in biosolids. Odor panel results showed that the level of odors measured after longer term storage, was correlated to the shorter term TVOSC concentrations. Mechanistically this was expected since the short term TVOSCs and longer term odorants are produced by similar pathways.
Several amendments added to centrifuge cake were able to significantly reduce odors and/or regrowth. The incubation of anaerobically digested biosolids with protein degrading enzymes resulted in additional gas production as well as a reduction in odors after dewatering. Also, better digestion was associated with lower odors, and primary sludges produced greater odors compared to secondary sludges.

Includes bibliographical references.

Description based on online resource; title from PDF title page (ebrary, viewed November 15, 2016).

Electronic reproduction. Ann Arbor, MI : ProQuest, 2016. Available via World Wide Web. Access may be limited to ProQuest affiliated libraries.

There are no comments on this title.

to post a comment.